Analysis of the thermal bridge of wood-aluminium window installation position
SYS 0112483 LBL 00000naa^^22^^^^^^^^450 005 20211103090632.2 017 70
$a 10.17423/afx.2021.63.2.08 $2 DOI 100 $a 20170407d m y0sloc0103 ba 101 0-
$a eng 102 $a SK 200 1-
$a Analysis of the thermal bridge of wood-aluminium window installation position $f Roman Nôta, Zuzana Danihelová 215 $c Graf., obr., tab. 330 $a Low-energy houses and passive houses are characterised by having building envelopes with low thermal resistance. Windows of such buildings are required to meet higher demands in terms of heat thermal as well. The window installed in the wall creates a structural thermal bridge, whose size is strongly affected by the thermal performance of the structural components as well as by the position of the window within the opening in the envelope. The objective of the paper was to analyse the impact of the window installation position in the envelope with various construction types and to determine the best possible place for installing the window. Mainly the position of the lower edge is discussed since this part demonstrates the worst values in terms of thermal performance. Due to the presence of the metal windowsill, the window frame is protected to a minimum extent by the outside insulation of the envelope. Therefore, the lower edge indicates the most significant thermal bridge. It was assumed that the most effective position of the window lower edge within the window opening, which has the lowest value of the linear thermal transmittance of the thermal bridge, is in places of the smallest deformation of the thermal field caused by window installation. The calculations showed that the proportion of the deformation size of the thermal field and the value of the linear thermal transmittance of window installation (Ψinstall.), in other words, their position in the structure, depend also on the curve direction of the temperature distribution in the envelope construction. 463 -1
$1 001 sldk_un_cat*0112179 $1 011 $a 1336-3824 $1 200 1 $a Acta Facultatis Xylologiae Zvolen $e vedecký časopis Drevárskej fakulty $v Vol. 63, no. 2 (2021), s. 93-102 $1 210 $a Zvolen $c Technická univerzita vo Zvolene $d 2021 541 1-
$a Analýza tepelného mosta pozície osadenia drevohliníkového okna 610 $9 sldk_un_auth*h006735 $a okná $X windows 610 $9 sldk_un_auth*h018588 $a drevo-hliníkové okná $X wood-aluminium windows 610 $9 sldk_un_auth*h042347 $a tepelné mosty $X thermal bridges 610 $9 sldk_un_auth*h005213 $a obalové konštrukcie $X covering constructions 610 $9 sldk_un_auth*0058675 $a lineárna tepelná priepustnosť $X linear thermal transmittance 675 $a 692.82 $v 1. stred. $z slo 675 $a 536.2 $v 1. stred. $z slo 675 $a 624.01 $v 1. stred. $z slo 700 -1
$3 sldk_un_auth*0005445 $a Nôta $b Roman $f 1982- $p TUZDFDIZ $4 070 $T Katedra dizajnu nábytku a interiéru 701 -1
$3 sldk_un_auth*0028205 $a Danihelová $b Zuzana $f 1986- $p TUZJA $4 070 $T Ústav cudzích jazykov 801 -0
$a SK $b ZV001 $c 20170407 $g AACR2 856 4-
$u https://df.tuzvo.sk/sites/default/files/08-02-21.pdf
Počet záznamov: 1