Výsledky vyhľadávania

Nájdených záznamov: 3  
Vaša požiadavka: Kľúčové slovo = "measurement uncertainty"
  1. NázovThe statistical uncertainty of the Heydemann correction: a practical limit of optical quadrature homodyne interferometry
    Aut.údajeReiner Koening, Gejza Wimmer, Viktor Witkovský
    Autor Koening Reiner (34%)
    Spoluautori Wimmer Gejza 1949- (33%) UMBFP10 - Katedra matematiky
    Witkovský Viktor (33%)
    Zdroj.dok. Measurement Science and Technology. Vol. 26, no. 8 (2015), pp. [1-12]. - Bristol : IOP Publishing, 2015
    Kľúč.slová Heydemanova korekcia   homodynná interferometria   neistota merania   Heydemann correction   homodyne interferometry   measurement uncertainty  
    Jazyk dok.angličtina
    KrajinaVeľká Británia
    Systematika 51
    Kategória publikačnej činnosti ADC
    Číslo archívnej kópie34041
    Kategória ohlasu XIA, Hao Jie - HU, Meng Wen - ZHANG, Xin. High precision processing of quadrature signals for homodyne interferometer. In Guangxue jingmi Gongcheng/Optics and precision engineering. ISSN 1004-924X, 2017, vol. 25, no. 9, pp. 2309-2316.
    BARRAUD, C. - GARCIA, L. - CROSS, B. - CHARLAIX, E. Real-time single analog output for quadrature phase interferometry. In Measurement science and technology. ISSN 0957-0233, 2017, vol. 28, 4.
    HORI, Yasuaki - GONDA, Satoshi - BITOU, Youichi - WATANABE, Akihiro - NAKAMURA, Koutaro. Periodic error evaluation system for linear encoders using a homodyne laser interferometer with 10 picometer uncertainty. In Precision engineering-journal of the international societies for precision engineering and nanotechnology. ISSN 0141-6359, 2018, vol. 51, pp. 388-392.
    Katal.org.BB301 - Univerzitná knižnica Univerzity Mateja Bela v Banskej Bystrici
    Báza dátxpca - PUBLIKAČNÁ ČINNOSŤ
    OdkazyPERIODIKÁ-Súborný záznam periodika
    nerozpoznaný

    nerozpoznaný

  2. NázovEllipse fitting by nonlinear constraints to demodulate quadrature homodyne interferometer signals and to determine the statistical uncertainty of the interferometric phase
    Aut.údajeRainer Köning, Gejza Wimmer, Viktor Witkovský
    Autor Köning Rainer (34%)
    Spoluautori Wimmer Gejza 1949- (33%) UMBFP10 - Katedra matematiky
    Witkovský Viktor (33%)
    Zdroj.dok. Measurement Science and Technology. Vol. 25, no. 11 (2014), pp. [1-11]. - Bristol : IOP Publishing, 2014
    Kľúč.slová Heydemann correction   homodyne interferometry   measurement uncertainty  
    Jazyk dok.angličtina
    KrajinaVeľká Británia
    Systematika 51
    Kategória publikačnej činnosti ADC
    Číslo archívnej kópie31086
    Kategória ohlasu HU, Pengcheng - ZHU, Jinghao - ZHAI, Xiaoyu - TAN, JiuBin. DC-offset-free homodyne interferometer and its nonlinearity compensation. In Optics express. ISSN 1094-4087, 2015, vol. 23, no. 7, pp. 8399-8408.
    XIA, Hao Jie - HU, Meng Wen - ZHANG, Xin. High precision processing of quadrature signals for homodyne interferometer. In Guangxue jingmi Gongcheng/Optics and precision engineering. ISSN 1004-924X, 2017, vol. 25, no. 9, pp. 2309-2316.
    BARRAUD, C. - GARCIA, L. - CROSS, B. - CHARLAIX, E. Real-time single analog output for quadrature phase interferometry. In Measurement science and technology. ISSN 0957-0233, 2017, vol. 28, 4.
    HU, Pengcheng - WANG, Yue - FU, Haijin - ZHU, Jinghao - TAN, Jiubin. Nonlinearity error in homodyne interferometer caused by multi-order Doppler frequency shift ghost reflections. In Optics express. ISSN 1094-4087, 2017, vol. 25, no. 4, pp. 3605-3612.
    FU, Haijin - HU, Pengcheng - TAN, Jiubin - FAN, Zhigang. Nonlinear errors induced by intermodulation in heterodyne laser interferometers. In Optics letters. ISSN 0146-9592, 2017, vol. 42, no. 3, pp. 427-430.
    YAN, Liping - CHEN, Benyong - CHEN, Zhouqiang - XIE, Jiandong - ZHANG, Enzheng - ZHANG, Shihua. Phase-modulated dual-homodyne interferometer without periodic nonlinearity. In Measurement science and technology. ISSN 0957-0233, 2017, vol. 28, no. 11.
    YAN, Liping - CHEN, Zhouqiang - CHEN, Benyong - XIE, Jiandong - ZHANG, Shihua - LOU, Yingtian - ZHANG, Enzheng. Precision PGC demodulation for homodyne interferometer modulated with a combined sinusoidal and triangular signal. In Optics express. ISSN 1094-4087, 2018, vol. 26, no. 4, pp. 4818-4831.
    Katal.org.BB301 - Univerzitná knižnica Univerzity Mateja Bela v Banskej Bystrici
    Báza dátxpca - PUBLIKAČNÁ ČINNOSŤ
    OdkazyPERIODIKÁ-Súborný záznam periodika
    nerozpoznaný

    nerozpoznaný

  3. NázovDetermining the Confidence Interval for the Center and Width of a Structure in Fitting Measured Data by the Regression Line
    Aut.údajeGejza Wimmer, Karol Karovič
    Autor Wimmer Gejza 1949- (50%) UMBFP10 - Katedra matematiky
    Spoluautori Karovič Karol (50%)
    Zdroj.dok. Measurement 2009 : 7th International conference on measurement, May 20-23, 2009 Smolenice Castle : proceedings. S. 45-48. - Bratislava : Institute of Measurement Science, Slovak Academy of Sciences, 2009 / Tyšler Milan ; Maňka Ján ; Witkovský Viktor
    PoznámkaBibl.: s. 48
    Kľúč.slová konfidenčné intervaly   neistota merania   confidence intervals   measurement uncertainty  
    Jazyk dok.angličtina
    KrajinaSlovenská republika
    Systematika 51
    AnotáciaOdvodené sú vhodné konfidenčné intervaly pre stred a šírku štruktúry. Proper confidence intervals are derived for width and center of a structure
    Kategória publikačnej činnosti AFD
    Číslo archívnej kópie13242
    Katal.org.BB301 - Univerzitná knižnica Univerzity Mateja Bela v Banskej Bystrici
    Báza dátxpca - PUBLIKAČNÁ ČINNOSŤ
    nerozpoznaný

    nerozpoznaný



  Tieto stránky využívajú súbory cookies, ktoré uľahčujú ich prezeranie. Ďalšie informácie o tom ako používame cookies.